{"id":3158,"date":"2012-11-06T17:16:26","date_gmt":"2012-11-06T09:16:26","guid":{"rendered":"http:\/\/www.g4e.cn\/wordpress\/?p=3158"},"modified":"2013-11-15T14:20:35","modified_gmt":"2013-11-15T06:20:35","slug":"the-adhesive-rheology-american-astm-standard-directory","status":"publish","type":"post","link":"http:\/\/www.g4e.cn\/wordpress\/adhesiveknowledge\/3158.html","title":{"rendered":"\u4e0e\u80f6\u7c98\u5242\u6d41\u53d8\u5b66\u76f8\u5173\u7684\u7f8e\u56fdASTM\u6807\u51c6\u76ee\u5f55"},"content":{"rendered":"<p><strong>\u4eca\u5929\u5728\u7f51\u4e0a\u67e5\u627e\u4e00\u4e9b\u6807\u51c6\u65f6\u53d1\u73b0\u4e86\u4e00\u4efd\u4e0e\u80f6\u7c98\u5242\u6d41\u53d8\u5b66\uff08\u7c98\u5ea6\u3001\u89e6\u53d8\u7b49\uff09\u76f8\u5173\u7684\u7f8e\u56fdASTM\u6807\u51c6\u76ee\u5f55\uff0c\u7f57\u5217\u5982\u4e0b\uff0c\u4f9b\u5927\u5bb6\u53c2\u8003\uff01<\/strong><\/p>\n<p><strong>1. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM C 965-1996<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u8f6f\u5316\u70b9\u4ee5\u4e0a\u7684\u73bb\u7483\u7c98\u5ea6\u7684\u6d4b\u5b9a\u7684\u6807\u51c6\u5b9e\u65bd\u89c4\u7a0b<!--more--><\/strong><strong><\/strong><\/p>\n<p><strong>Practice for Measuring Viscosity of Glass Above the Softening Point <\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>2. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM<\/strong><strong>\uff1a\u7f8e\u56fd\u6750\u6599\u4e0e\u8bd5\u9a8c\u534f\u4f1a<\/strong><strong>ASTM C 1276-1994<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u5229\u7528\u65cb\u8f6c\u7c98\u5ea6\u8ba1\u6d4b\u91cf\u6a21\u5236\u7c89\u672b\u7194\u70b9\u4ee5\u4e0a\u7c98\u5ea6\u7684\u6807\u51c6\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Standard Test Method for Measuring the Viscosity of Mold Powders Above their Melting Point Using a Rotaional Viscometer<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>3. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 115-2002<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u7535\u7edd\u7f18\u7528\u6e05\u6f06\u7684\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Methods of Testing Varnishes Used for electrical Insulation<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>4. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 562-2001<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u65af\u6258\u9ed8\u7c98\u5ea6\u8ba1\u6d4b\u5b9a\u6d82\u6599\u7a20\u5ea6\u7684\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Standard Test Method for Consistency of Paints Using for Stormer Viscometer<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>5. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 789-1998<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u6d4b\u5b9a\u805a\u9170\u80fa\u7684\u76f8\u5bf9\u7c98\u5ea6\u3001\u878d\u70b9\u548c\u542b\u6e7f\u91cf\u7684\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Test Methods for determination of Relative Viscosity, Melting Point, and Moisture Content of Polyamide(PA)<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>6. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 1076-1988<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u6a61\u80f6<\/strong><strong>.<\/strong><strong>\u6d53\u7f29\u7684\u3001\u6c28\u50a8\u5b58\u7684\u3001\u4e73\u72b6\u7684\u548c\u79bb\u5fc3\u5904\u7406\u7684\u5929\u7136\u80f6\u4e73\u7684\u6807\u51c6\u89c4\u8303<\/strong><strong><\/strong><\/p>\n<p><strong>specification for Rubber-Concentrated, Ammonia Preserved,Creamed and Centrifuged Natural latex<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>7. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 1084-1997<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u80f6\u7c98\u5242\u7c98\u5ea6\u7684\u6d4b\u8bd5\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Test Methods for Viscosity of adhesives<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>8. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 1417-2003<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u5408\u6210\u6a61\u80f6\u80f6\u4e73\u7684\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Methods of Testing Rubber Latices-Synthetic<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>9. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 1439-2003<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u7fa7\u7532\u57fa\u7ea4\u7ef4\u7d20\u94a0\u76d0\u7684\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Methods of Testing Sodium Carboxymethyl-Cellulose<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>10. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 1824-1995<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u5728\u4f4e\u526a\u5207\u901f\u7387\u4e0b\u5851\u6599\u6eb6\u80f6\u548c\u6709\u673a\u6eb6\u80f6\u7684\u8868\u89c2\u7c98\u5ea6\u7684\u6807\u51c6\u6d4b\u8bd5\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Test Method For Apparent Viscosity of Plastisols and Organosols at Low Shear Rates by Brookfield Viscometer<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>11. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 2196-1999<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u65cb\u8f6c<\/strong><strong>(Brookfield)<\/strong><strong>\u7c98\u5ea6\u8ba1\u6d4b\u5b9a\u975e\u725b\u987f\u6750\u6599\u6d41\u53d8\u6027\u80fd\u7684\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Test Methods for Rehological Properties on Non-Newtonian Materials by Rotational(Brookfield) Viscometer<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>12. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 2364-2001<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u7f9f\u57fa\u4e59\u57fa\u7ea4\u7ef4\u7d20\u7684\u6807\u51c6\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Standard Methods of Testing Hydroxyethyl-Cellulose<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>13. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 2393-1986<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u73af\u6c27\u6811\u8102\u548c\u76f8\u5173\u6210\u5206\u7c98\u5ea6\u7684\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Test Method For Viscosity of Epoxy Resins and Related Components<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>14. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 2556-1993<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u7528\u5207\u53d8\u901f\u7387\u51b3\u5b9a\u5176\u6d41\u52a8\u6027\u80fd\u7684\u80f6\u7c98\u5242\u7684\u8868\u89c2\u7c98\u5ea6\u7684\u6807\u51c6\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Test Method For Apparent Viscosity of Adhesives Having Shear Rate Dependent Flow Properties<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>15. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 2983-2004<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u7528<\/strong><strong>Brookfield<\/strong><strong>\u7c98\u5ea6\u8ba1\u6d4b\u91cf\u6da6\u6ed1\u5242\u4f4e\u6e29\u7c98\u5ea6\u7684\u6807\u51c6\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Test Method for Low-Temperature Visosity of Automotive Fluid Lubricants Measured by the Brookfield Viscometer<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>16. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 3236-1988<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u70ed\u7194\u7c98\u5408\u5242\u53ca\u6d82\u5c42\u6750\u6599\u8868\u89c2\u7c98\u5ea6\u7684\u6807\u51c6\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Test Method for Apparent Viscosity of Hot Melt Adhesives and Coating Materials<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>17. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 3468-1999<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u5c4b\u9762\u548c\u9632\u6c34\u7528\u6db2\u4f53\u6c2f\u4e01\u6a61\u80f6\u53ca\u6c2f\u78fa\u5316\u805a\u4e59\u70ef\u6807\u51c6\u89c4\u8303<\/strong><strong><\/strong><\/p>\n<p><strong>Standard Specification for Liquid-Applied Neoprene and Chlorosulfonated Polyethylene Used in Roofing and Waterproofing<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>18. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 3716-1999<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u5730\u677f\u629b\u5149\u5242\u7528\u4e73\u5316\u805a\u5408\u7269\u7684\u6807\u51c6\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Method of testing Emulsion Polymer for Use in Floor Polishes<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>19. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 3791-2004<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u8bc4\u4ef7\u70ed\u5bf9\u6ca5\u9752\u5f71\u54cd\u7684\u6807\u51c6\u5b9e\u65bd\u89c4\u7a0b<\/strong><strong><\/strong><\/p>\n<p><strong>Standard Practice for Evaluating the Effects of Heat on Asphalts<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>20. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 4016-2002<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u7528<\/strong><strong>Brookfield<\/strong><strong>\u7c98\u5ea6\u8ba1\u6d4b\u5b9a\u5316\u5b66\u704c\u6d46\u7c98\u5ea6\u7684\u6807\u51c6\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong>(<\/strong><strong>\u5b9e\u9a8c\u5ba4\u6cd5<\/strong><strong>)<\/strong><\/p>\n<p><strong>Test Method For Viscosity of Chemical Grouts by the Brookfield Viscometer(Laboratory Method)<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>21. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 4287-2000<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u7528\u9525\u677f\u7c98\u5ea6\u8ba1\u6d4b\u5b9a\u9ad8\u901f\u526a\u5207\u7c98\u5ea6\u7684\u6807\u51c6\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Standard Test Method for High-Shear Viscosity Using the ICI Cone\/Plate Viscometer<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>22. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 4300-2001<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u9709\u83cc\u6c61\u67d3\u5bf9\u80f6\u7c98\u5236\u5242\u53ca\u80f6\u7c98\u819c\u7684\u8010\u4e45\u6027\u5f71\u54cd\u7684\u6d4b\u8bd5\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Test Method for Effect of Mold Contamination on Permanence of Adhesive Preparations and Adhesives Films<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>23. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 4402-2002<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u4f7f\u7528<\/strong><strong>Brookfield Thermosel<\/strong><strong>\u4eea\u5668\u6d4b\u5b9a\u975e\u586b\u5145\u6ca5\u9752\u7c98\u5ea6\u7684\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Standard Methods for Viscositu Determinationgs of Unfilled Asphalts Using the Brookfield Thermoesel Apparatus<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>24. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 4889-2004<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u805a\u6c28\u57fa\u7532\u9178\u4e59\u916f\u539f\u6750\u6599\u7684\u6807\u51c6\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong>:<\/strong><strong>\u5f02\u6c30\u9178\u916f\u6216\u6539\u6027\u5f02\u6c30\u9178\u916f\u7c98\u5ea6\u6d4b\u5b9a<\/strong><strong><\/strong><\/p>\n<p><strong>Standard Test Method for Polyurethane Raw Materials:Determination of Viscosity of Crude or Modified Isocyanates<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>25. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 5018-1989<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u7164\u7126\u6cb9\u548c\u77f3\u6cb9\u786c\u6ca5\u9752\u526a\u5207\u7c98\u5ea6\u7684\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Standard Test Method for Shear viscosity of Coal-Tar and Petroleum Pitches<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>26. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 5133-2005<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u6e29\u5ea6\u626b\u63cf\u6280\u672f\u6d4b\u8bd5\u6da6\u6ed1\u6cb9\u7684\u4f4e\u6e29\u3001\u4f4e\u526a\u5207\u7387\u3001\u7c98\u6027<\/strong><strong>\/<\/strong><strong>\u6e29\u5ea6\u4f9d\u8d56\u6027\u7684\u6807\u51c6\u8bd5\u9a8c\u65b9\u6cd5<\/strong><strong><\/strong><\/p>\n<p><strong>Standard Test Method for Low Temperature, Low Shear Rate, Viscosity\/Temperature Dependence of Lubricating Oils Using a Temperature-Scanning Technique<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>27. <\/strong><strong>\u6807\u51c6\u53f7\uff1a<\/strong><strong>ASTM D 6080-1997<\/strong><\/p>\n<p><strong>\u4e2d\u6587\u540d\u79f0\uff1a\u6db2\u538b\u6d41\u4f53\u7c98\u6ede\u7279\u6027\u5b9a\u4e49\u7684\u6807\u51c6\u64cd\u4f5c<\/strong><strong><\/strong><\/p>\n<p><strong>Standard Practice for Defining the Viscosity Characteristics of Hydraulic Fluids<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u4eca\u5929\u5728\u7f51\u4e0a\u67e5\u627e\u4e00\u4e9b\u6807\u51c6\u65f6\u53d1\u73b0\u4e86\u4e00\u4efd\u4e0e\u80f6\u7c98\u5242\u6d41\u53d8\u5b66\uff08\u7c98\u5ea6\u3001\u89e6\u53d8\u7b49\uff09\u76f8\u5173\u7684\u7f8e\u56fdASTM\u6807\u51c6\u76ee\u5f55\uff0c\u7f57\u5217\u5982\u4e0b\uff0c\u4f9b\u5927\u5bb6\u53c2 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3517,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[671],"tags":[657,240,658],"_links":{"self":[{"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/posts\/3158"}],"collection":[{"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/comments?post=3158"}],"version-history":[{"count":0,"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/posts\/3158\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/media\/3517"}],"wp:attachment":[{"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/media?parent=3158"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/categories?post=3158"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/tags?post=3158"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}