{"id":2787,"date":"2011-12-06T22:02:51","date_gmt":"2011-12-06T14:02:51","guid":{"rendered":"http:\/\/www.g4e.cn\/wordpress\/?p=2787"},"modified":"2013-11-19T15:47:46","modified_gmt":"2013-11-19T07:47:46","slug":"ablestik-conductive-silver-glue-ablebond-8380b-tds","status":"publish","type":"post","link":"http:\/\/www.g4e.cn\/wordpress\/datasheet\/2787.html","title":{"rendered":"Ablestik\u5bfc\u7535\u94f6\u80f6ABLEBOND 8380B TDS"},"content":{"rendered":"<pre>PRODUCT DESCRIPTION\r\nABLEBOND 8380B provides the following product\r\ncharacteristics:\r\nTechnology Epoxy\r\nAppearance Silver\r\nCure Heat cure\r\nProduct Benefits \u2022 Electrically conductive\r\n\u2022 Fast cure at low temperatures\r\n\u2022 Low resin bleed\r\nApplication Die attach\r\nFiller Type Silver\r\nTypical Package\r\nApplication\r\nCharge Couple Device (CCD)\r\nABLEBOND 8380B adhesive is designed for medium die\r\nattach applications.\r\nTYPICAL PROPERTIES OF UNCURED MATERIAL\r\nThixotropic Index (0.5\/5 rpm) 2.0\r\nViscosity, Brookfield CP51, 25 \u00b0C, mPa\u00b7s (cP):\r\nSpeed 5 rpm 10,000\r\nWork Life @ 25\u00b0C, hours 48\r\nShelf Life @ -40\u00b0C (from date of manufacture), year 1\r\nTYPICAL CURING PERFORMANCE\r\nCure Schedule\r\n15 minutes @ 150\u00b0C\r\nThe above cure profiles are guideline recommendations. Cure\r\nconditions (time and temperature) may vary based on customers'\r\nexperience and their application requirements, as well as customer\r\ncuring equipment, oven loading and actual oven temperatures.\r\nTYPICAL PROPERTIES OF CURED MATERIAL\r\nElectrical Properties:\r\nVolume Resistivity, ohms-cm 0.0002\r\nTYPICAL PERFORMANCE OF CURED MATERIAL\r\nDie Shear Strength:\r\n2 X 2 mm , psi,\r\ncured 15 minutes @ 150\u00baC\r\nSubstrate\r\nAg\/Cu Leadframe 1400<\/pre>\n<pre>GENERAL INFORMATION\r\nFor safe handling information on this product, consult the\r\nMaterial Safety Data Sheet, (MSDS).\r\nTHAWING:\r\n1. Allow container to reach room temperature before use.\r\n2. After removing from the freezer, set the syringes to stand\r\nvertically while thawing.\r\n3. Refer to the Syringe Thaw time chart for the thaw time\r\nrecommendation.\r\n4. DO NOT open the container before contents reach 25\u00b0C\r\ntemperature. Any moisture that collects on the thawed\r\ncontainer should be removed prior to opening the\r\ncontainer.\r\n5. DO NOT re-freeze. Once thawed to -40\u00b0C, the adhesive\r\nshould not be re-frozen.\r\nTemperature, \u00b0C\r\nSyringe Thaw Time, Minutes\r\n30\r\n20\r\n10\r\n0\r\n-10\r\n-20\r\n-30\r\n-40\r\n0 10 20 30 40 50\r\n1cc\r\n3cc 10cc 30cc\r\nDIRECTIONS FOR USE\r\n1. Thawed adhesive should be immediately placed on\r\ndispense equipment for use.\r\n2. If the adhesive is transferred to a final dispensing\r\nreservoir, care must be exercised to avoid entrapment of\r\ncontaminants and\/or air into the adhesive.\r\n3. Adhesive must be completely used within the products\r\nrecommended work life of 24 hours.\r\n4. Silver-resin separation may occur if the adhesive is left\r\nout at 25\u00b0C beyond the recommended work life.\r\nNot for product specifications\r\nThe technical data contained herein are intended as reference\r\nonly. Please contact your local quality department for\r\nassistance and recommendations on specifications for this\r\nproduct.<\/pre>\n<pre>Storage\r\nStore product in the unopened container in a dry location.\r\nStorage information may be indicated on the product container\r\nlabeling.\r\nOptimal Storage: -40 \u00b0C. Storage below minus (-)40 \u00b0C or\r\ngreater than minus (-)40 \u00b0C can adversely affect product\r\nproperties.\r\nMaterial removed from containers may be contaminated during\r\nuse. Do not return product to the original container. Henkel\r\nCorporation cannot assume responsibility for product which\r\nhas been contaminated or stored under conditions other than\r\nthose previously indicated. If additional information is required,\r\nplease contact your local Technical Service Center or\r\nCustomer Service Representative.\r\nConversions\r\n(\u00b0C x 1.8) + 32 = \u00b0F\r\nkV\/mm x 25.4 = V\/mil\r\nmm \/ 25.4 = inches\r\nN x 0.225 = lb\r\nN\/mm x 5.71 = lb\/in\r\nN\/mm\u00b2 x 145 = psi\r\nMPa x 145 = psi\r\nN\u00b7m x 8.851 = lb\u00b7in\r\nN\u00b7m x 0.738 = lb\u00b7ft\r\nN\u00b7mm x 0.142 = oz\u00b7in\r\nmPa\u00b7s = cP\r\nNote\r\nThe data contained herein are furnished for information only\r\nand are believed to be reliable. We cannot assume\r\nresponsibility for the results obtained by others over whose\r\nmethods we have no control. It is the user's responsibility to\r\ndetermine suitability for the user's purpose of any production\r\nmethods mentioned herein and to adopt such precautions as\r\nmay be advisable for the protection of property and of persons\r\nagainst any hazards that may be involved in the handling and\r\nuse thereof. In light of the foregoing, Henkel Corporation\r\nspecifically disclaims all warranties expressed or implied,\r\nincluding warranties of merchantability or fitness for a\r\nparticular purpose, arising from sale or use of Henkel\r\nCorporation\u2019s products. Henkel Corporation specifically\r\ndisclaims any liability for consequential or incidental\r\ndamages of any kind, including lost profits. The discussion\r\nherein of various processes or compositions is not to be\r\ninterpreted as representation that they are free from\r\ndomination of patents owned by others or as a license under\r\nany Henkel Corporation patents that may cover such\r\nprocesses or compositions. We recommend that each\r\nprospective user test his proposed application before repetitive\r\nuse, using this data as a guide. This product may be covered\r\nby one or more United States or foreign patents or patent\r\napplications.<\/pre>\n<pre>\u4e0b\u8f7d\u9644\u4ef6\u53c2\u770bPDF\u7248\u672c\uff1a<p><img src=\"http:\/\/www.g4e.cn\/wordpress\/wp-content\/plugins\/hacklog-downloadmanager\/images\/ext\/pdf.gif\" alt=\"\" title=\"\" style=\"vertical-align: middle;\" \/>&nbsp;&nbsp;<strong>ABLEBOND 8380B-EN<\/strong> (61.8 KB, 6 \u6b21)<br \/><i>\u60a8\u6ca1\u6709\u6743\u9650\u4e0b\u8f7d\u6b64\u6587\u4ef6\u3002<\/i><\/p><\/pre>\n","protected":false},"excerpt":{"rendered":"<p>PRODUCT DESCRIPTION ABLEBOND 8380B provides the followi [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3748,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[667],"tags":[469,468,467,470],"_links":{"self":[{"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/posts\/2787"}],"collection":[{"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/comments?post=2787"}],"version-history":[{"count":0,"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/posts\/2787\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/media\/3748"}],"wp:attachment":[{"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/media?parent=2787"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/categories?post=2787"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.g4e.cn\/wordpress\/wp-json\/wp\/v2\/tags?post=2787"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}